Embedded Capacity Register - December 2020
All distributed generation with a capacity of 1MW or above captured in a consolidated format including generator type, location, capacity and wider key information.
Data Dictionary
Title | Type | Label | Description | Example |
---|---|---|---|---|
GD MPAN | text | nan | The core meter point administration number, a 13-digit reference used in MPAS to identify the relevant Metering Point. |
2.1E+12 |
GD Customer Name | text | nan | The core meter point administration number, a 13-digit reference used in MPAS to identify the relevant Metering Point. |
AB InBev UK Limited |
GD Customer Site | text | nan | Name of customer site/project name. |
CE RUSH WALL TURBINE LIMITED |
GD Address Line 1 | text | nan | Name of customer site/project name. |
WHITBREAD BREWERY |
GD Address Line 2 | text | nan | Address line 2 of the Customer Site. |
MAGOR |
GD Town/ City | text | nan | Town / City of the Customer Site. |
NEWPORT |
GD County | text | nan | County of the Customer Site. |
SHROPSHIRE |
GD Postcode | text | nan | Postcode of the Customer Site. |
NP26 3DA |
GD Country | text | nan | Country of the Customer Site. |
United Kingdom |
GD Location (X-coordinate): Eastings (where data is held) | numeric | nan | Six digit British National Grid X coordinate of the Customer Site. |
321941.398 |
GD Location (y-coordinate): Northings (where data is held) | numeric | nan | Six or seven digit British National Grid Y coordinate of the Customer Site. |
162247.701 |
GD Grid Supply Point | text | nan | The point of connection between the transmission system and the distribution system that is linked with the Customer Site. |
Uskmouth |
GD Bulk Supply Point | text | nan | The supply point on the distribution system (representing an EHV/EHV transformation level) that is linked with the Customer Site. |
Magor |
GD Primary | text | nan | The primary substation on the distribution system that is linked with the Customer Site. |
Trowbridge Primary |
GD Point of Connection (POC) Voltage (kV) | numeric | kV | The voltage at the Point of Connection to the distribution system. |
11 |
GD Licence Area | text | nan | Licence area Customer Site is connected within |
National Grid Electricity Distribution (East Midlands) Plc |
GD Primary Resource Type | text | nan | The energy source type used in the production of electricity |
Wind |
GD Primary Technology/ Plant Type | text | nan | The technology type that export electricity onto a distribution system |
Onshore wind turbines |
GD CHP Cogeneration | text | nan | Indicates whether the generation in the Customer Site forms part of a CHP scheme. |
No |
GD Storage Duration | numeric | Hours | Divide the storage capacity (MWh) by the Registered Capacity (MW) and round it down to the nearest 0.5 (half-hour) |
0 |
GD Primary Resource Type - Installed Capacity (MW) | numeric | MW | This is the Installed Capacity of the "Primary Resource" expressed in MW. |
11.307 |
GD Primary Resource Type - Installed Capacity (MVA): | numeric | MVA | This is the Installed Capacity of the "Primary Resource" expressed in MVA |
10.742 |
GD Resource Type 2 | text | nan | Where there is more than one plant type at a site, the "Energy Source 2" and "Energy Source 3" fields would be used to show the energy source types additional to the "Energy Source 1". |
Solar |
GD Technology / Plant Type 2 | text | nan | Where there is more than one plant type at a site, the "Energy Source 2" and "Energy Source 3" fields would be used to show the energy source types additional to the "Energy Source 1". |
Photovoltaic |
GD CHP Cogeneration Type 2 | text | nan | Indicates whether the generation in the Customer Site forms part of a CHP scheme. |
Yes |
GD Storage Duration Type 2 | text | Hours | Divide the storage capacity (MWh) by the Registered Capacity (MW) and round it down to the nearest 0.5 (half-hour). |
5 |
GD Resource Type 2 - Installed Capacity (MW) | text | MW | This is the Installed Capacity of the "Resource Type 2" expressed in MW. |
4 |
GD Resource Type 2 - Installed Capacity (MVA) | text | MVA | This is the Installed Capacity of the "Resource Type 2" expressed in MVA |
3.8 |
GD Resource Type 3 | text | nan | Where there is more than one plant type at a site, the "Energy Source 2" and "Energy Source 3" fields would be used to show the energy source types additional to the "Energy Source 1". |
Biofuel landfill gas |
GD Technology / Plant Type 3 | text | nan | Defined for “Energy Conversion Technology 1”. |
Gas turbine (OCGT) |
GD CHP Cogeneration Type 3 | text | nan | Indicates whether the generation in the Customer Site forms part of a CHP scheme. |
No |
GD Storage Duration Type 3 | text | Hours | Divide the storage capacity (MWh) by the Registered Capacity (MW) and round it down to the nearest 0.5 (half-hour). |
5 |
GD Resource Type 3 - Installed Capacity (MW) | text | MW | This is the Installed Capacity of the "Resource Type 3" expressed in MW. |
3 |
GD Resource Type 3 - Installed Capacity (MVA) | text | MVA | This is the Installed Capacity of the "Resource Type 3" expressed in MVA |
2.85 |
GD Flexible Connection (Yes/No) | text | nan | Indicates whether the connection is subject to a flexible connection arrangement e.g. Active Network Management (ANM) during system normal conditions. |
No |
GD Connection Status | text | nan | Connected" or "Accepted to Connect"? |
Connected |
GD Last Updated | timestamp | DD/MM/YYYY | Date on which entry was last updated. |
12/10/2021 |
AC Installed Generation Capacity (MVA) | numeric | MW | This is the total Registered Capacity of generation already connected at the site expressed in MW. |
11.902 |
AC Export Capacity (MW) | numeric | MW | This is the total MW export capacity permitted as per the connection agreement. |
3.325 |
AC Export Capacity (MVA) | numeric | MVA | This is the total MVA export capacity permitted as per the connection agreement. |
3.5 |
AC Import Capacity (MW) | numeric | MW | This is the total MW import capacity permitted as per the connection agreement. |
6.65 |
AC Import Capacity (MVA) | numeric | MVA | This is the total MVA export capacity permitted as per the connection agreement. |
7 |
AC Date Connected | timestamp | DD/MM/YYYY | Date the connection was provided in the case of a new connection. In cases where there was an existing connection, this is date the new equipment was connected |
01/07/1990 |
AtC AtC Generation Capacity (MVA) | text | MW | This is the Registered Capacity of generation that is not already connected, but has been Accepted to Connect, expressed in MW. |
126.316 |
AtC Export Capacity (MW) | text | MW | This is the new/additional MW export capacity (i.e. not yet connected) that has been accepted to connect as per the connection agreement. |
60 |
AtC Export Capacity (MVA) | text | MVA | This is the new/additional MW export capacity (i.e. not yet connected) that has been accepted to connect as per the connection agreement. |
63.158 |
AtC Import Capacity (MW) | text | MW | This is the new/additional MW import capacity (i.e. not yet connected) that has been accepted to connect as per the connection agreement. |
60 |
AtC Import Capacity (MVA) | text | MVA | This is the new/additional MVA import capacity (i.e. not yet connected) that has been accepted to connect as per the connection agreement. |
63.158 |
AtC Date Accepted | text | DD/MM/YYYY | Date the Customer accepted the connection offer from the DNO or IDNO. |
02/12/2020 |
AtC Target Energisation Date | text | DD/MM/YYYY | Estimated date of energisation. This date is likely to change to reflect the latest date notified by customers. |
01/01/2023 |
Services Provided Distribution Service Provider (Y/N) | text | nan | Indicates whether a service is provided to the DNO. |
N |
Services Provided Transmission Service Provider (Y/N) | text | nan | Indicates whether a service is provided to the ESO or a TO. |
N |
Services Provided Reference | text | nan | Unique reference to the service(s) being provided. |
TSPREF1 |
Reinforcement Works In a Connection Queue (Y/N) | text | nan | Indicates whether the connection to the Customer Site is in a connection queue. |
Y |
Reinforcement Works Distribution Reinforcement Reference | text | nan | Unique reference to relevant distribution reinforcement required for connection. |
DREF1 |
Reinforcement Works Transmission Reinforcement Reference | text | nan | Unique reference to relevant transmission reinforcement required for connection. |
TREF1 |